6.2.5.4 ENABLING DATA SENDING
Command Notes
Command @ENABLERTM# Enables sending data to the Unity Self.
Table 39
6.2.5.5 DISABLING DATA SENDING
Command Notes
Command @DISABLERTM# Disables sending data to the Unity Self.
Table 40
6.2.6 EQUIPMENT CALIBRATION
6.2.6.1 READING THE ADC VALUE OF THE KNOB POSITION
Command Notes
Command @RKNOBPOSVL lvl#
Shows the memorized ADC value, which corre-
sponds with the indicated position of the knob.
Table 41
The parameter lvl indicates the position of the knob. The possible values are:
1: Position of minimum resistance (ROWING mode);
10: Position of maximum resistance (ROWING mode);
11: Position of the rst magnet (POWER mode);
12: Position of the second magnet (POWER mode);
13: Position of the third magnet (POWER mode).
SKILLROW:
Technical Service Guide - Rev. 1.1
Page 49e-mail: support@technogym.com