EasyManuals Logo
Home>Tektronix>Test Equipment>465M

Tektronix 465M User Manual

Tektronix 465M
236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
AIR
FORCE
T033A1-13-496-1
NAVELEX
0969-LP-l
70-0010
Operation
Instructions
IN
STARTS
AFTER DELAY,
THE
I
B
SWEEP GATE
AND
B DELAYED
GATE
I
OCCUR AT
THE SAME
TIME.
I
A
SWEEP RAMP
PIN 2 OF U2790
B DELAYED
GATE
PIN
16 OF
U2790.
DELAY TIME POS
SET
TO ABOUT
2.00
B SWEEP GATE
PIN 14 OF
U2160
B
SWP GATE
BASE OF
Q2622
B
RAMP
PIN 2 OF U2690
PARTIAL +B
GATE
OUT
PIN 19
OF
U2690
PARTIAL +B GATE
OUT
COLLECTOR OF 02602
THROUGH CR2690
+B
GATE
OUT
EMITTER OF
Q2696
B RAMP
PIN
2 OF U2690
PARTIAL +B GATE OUT
PIN
10 OF U2690
PARTIAL
+B GATE
OUT
COLLECTOR
OF 02602
THROUGH
CR2690
+B GATE OUT
EMITTER
OF Q2696
Figure
4-9.
Waveforms produced during B sweep generation
4-18