Commands Listed in Alphabetical Order
Examples
*OPC generates
the operation complete message in the SESR at the completion of
all pending OPC operations.
*OPC? might re
turn 1 to indicate that all pending OPC operations are finished.
*OPT? (Query Only)
This query-only command returns a list of the options installed in your instrument.
Group
Status and Error
Syntax
*OPT?
Examples
*OPT? might return :3M:16 Meg Max 4M/CH.
PASSWord (No Query Form)
This command (no query form) enables the *PUD and NEWpass set commands.
Sending PASSWord without any arguments disables these same commands. Once
the password is successfully entered, the *PUD and NEWpass commands are
enabled u ntil the instrument is powered off, or until the FACtory command, the
PASSWord command with no arguments, or the *RST command is issued.
To change the password, you must first enter the valid password with the
PASSWord command and then change to your new password with the NEWpass
command. Remember that the password is case sensitive.
Group
Miscellaneous
Syntax
PASSWord <QString>
Related Commands
NEWpass, *PUD
Arguments
<QString> is the p assword, which can contain up to 10 characters. The factory
default password is “XYZZY” and is always valid.
Examples
PASSWORD "XYZZY" enables the *PUD and NEWPass set commands.
PASSWORD disables the *PUD and NEWPass set commands. You can still use the
query version of *PUD.
2-412 DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual