Analyze Wavefor
mData
3. Use the side me
nu and the multipurpose
knobs to adjust the vertical and horizontal
settings of the reference waveform.
R1
Vertical
0.00 div
100 mV/div
Horizontal
0.00 s
4.00 μs/div
Quick Tips
Selecting and Displaying Reference Waveforms. You can display all the reference waveforms at the same time.
Push the appropriate screen button to select a particular reference waveform.
Removing Reference Waveforms from the Display. To remove a reference waveform from the display, push R on the
front-paneln to access the lower menu. Then push the associated button on the lower menu to turn it off.
Scaling and Positioning a Reference Waveform. You can position and scale a reference w aveform independently
from all other displayed waveforms. Select the reference waveform and then adjust it with a multipurpose knob. You can
do this whether acquisition is running or not.
If a reference w aveform is selected, scaling and repositioning of the reference waveform operates the same way
whether zoom is turned on or off.
Saving 5 M Reference Waveforms. 5 M reference waveforms are volatile and not saved when the oscilloscope power
is turned off. To keep these waveforms, save them to external storage.
MSO3000 and DPO 3000 Series Oscilloscopes User Manual 117