44 3. Programming
3.6.2 Built-in Siren Parameters Programming
Menu for the events where the built-in siren of the control panel
is activated. By default the events Alarm”, FIRE”, squawk
on full” (beeps in full arming) and “squawk on p a r t
(beeps in part arming) are programmed.
The duration of the siren signal is programmed. By default the
time is set at 2 min.
Use the
ENT
button to conrm all entered data and changes.
* All active parameters in the system are marked with the * symbol and the
inactive - with the -” symbol. Press the
PRG
button of the keypad to change the
parameter status of the respective submenu.
3.6.3 Entry Time Programming
The programmed Entry Time applies to all entry-exit groups and can be within the inter-
val of 0 - 255 seconds. By default the programmed Entry Time is 10 sec.
Use the
ENT
button to conrm the entered time.
3.6.4 Exit Time Programming
The programmed Exit Time applies to all entry-exit groups and can be within the interval
of 0 - 255 seconds. By default the programmed Exit Time is 20 sec.
Use the
ENT
button to conrm the entered time.
ENT
ENT
ENT
* Alarm
* FIRE
- Tamper
- Panic
- Module Lost
- Medical
* sqwk.on fARM
* sqwk.on pARM
2)Main Siren
1)System Events
1)System Events
* Alarm
7)System
2)Main Siren
2)Main Siren
2)Cut-Off time
2)Cut-Off time
2 minute
1 minute
2 minune
3 minute
4 minute
ENT
7)System
3)Entry Time
3)Entry time
in seconds:10
2
5
8
0
1
3
4
6
79
-
ENT
7)System
4)Exit Time
4)Exit Time
in seconds:20
2
5
8
0
1
3
4
6
79
-
*