Page #211 background image
August 2021 Service and Repair Manual
Type "FXXX" Faults
Part No. 1309020GT GS
-30m • 32m • 30 32 46 • 55 197
Type "FXXX" Faults, (continued)
DTC
Number
Message on
GCON LCD
Description Possible Causes Failure Mode
F012:
F012:SENSORFAULT
LEVEL PITCH:BAT+
Short circuit of the Level Pitch Sensor
circuit to battery positive.
• Short circuit in the level pitch sensor circuit.
• Faulty level sensor.
• GCON ECM.
All functions inhibited.
F013:
F013:SENSORFAULT
LEVEL PITCH:BAT-
Short circuit of the Level Pitch Sensor
circuit to battery negative.
• Short circuit in the level pitch sensor circuit.
• Faulty level sensor.
• GCON ECM.
All functions inhibited.
F014:
F014:SENSORFAULT
LEVEL ROLL:BAT+
Short circuit of the Level Roll Sensor
circuit to battery positive.
• Short circuit in the level roll sensor circuit.
• Faulty level sensor.
• GCON ECM.
All functions inhibited.
F015:
F015:SENSORFAULT
LEVEL ROLL:BAT-
Short circuit of the Level Roll Sensor
circuit to battery negative.
• Short circuit in the level roll sensor circuit.
• Faulty level sensor.
• GCON ECM.
All functions inhibited.
F016:
F016:SENSORFAULT
LF RIGGER:BAT+
Short circuit of the Left Front
Outrigger Sensor circuit to battery
positive.
• Short circuit in the left front outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
Left front outrigger inhibited if
outrigger extend is activated.
Outrigger can still be retracted.
F017:
F017:SENSORFAULT
LF RIGGER:BAT-
Short circuit of the Left Front
Outrigger Sensor circuit to battery
negative.
• Short circuit in the left front outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
Left front outrigger inhibited if
outrigger extend is activated.
Outrigger can still be retracted.
F018:
F018:SENSORFAULT
RF RIGGER:BAT+
Short circuit of the Right Front
Outrigger Sensor circuit to battery
positive.
• Short circuit in the right front outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
Right front outrigger inhibited if
outrigger extend is activated.
Outrigger can still be retracted.
F019:
F019:SENSORFAULT
RF RIGGER:BAT-
Short circuit of the Right Front
Outrigger Sensor circuit to battery
negative.
• Short circuit in the right front outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
Right front outrigger inhibited if
outrigger extend is activated.
Outrigger can still be retracted.
F020:
F020:SENSORFAULT
LR RIGGER:BAT+
Short circuit of the Left Rear
Outrigger Sensor circuit to battery
positive.
• Short circuit in the left rear outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
Left rear outrigger inhibited if
outrigger extend is activated.
Outrigger can still be retracted.
F021:
F021:SENSORFAULT
LR RIGGER:BAT-
Short circuit of the Left Rear
Outrigger Sensor circuit to battery
negative.
• Short circuit in the left rear outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
Left rear outrigger inhibited if
outrigger extend is activated.
Outrigger can still be retracted.
F022:
F022:SENSORFAULT
RR RIGGER:BAT+
Short circuit of the Right Rear
Outrigger Sensor circuit to battery
positive.
• Short circuit in the right rear outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
Right rear outrigger inhibited if
outrigger extend is activated.
Outrigger can still be retracted.

Table of Contents

Other manuals for Terex Genie GS-1330m

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Terex Genie GS-1330m and is the answer not in the manual?

Terex Genie GS-1330m Specifications

General IconGeneral
BrandTerex
ModelGenie GS-1330m
CategoryLifting Systems
LanguageEnglish

Related product manuals