August 2021 Service and Repair Manual
Battery Charger
Part No. 1309020GT GS
â„¢
-30m • 32m • 30 • 32 • 46 • 55 203
Charg er Er ror Cod es
Charger Error Codes
Description
Possible Causes
E-0-0-1 High battery voltage Battery voltage too high to charge. Check battery voltage and cable
connections.
Self clearing when condition has
been corrected.
E-0-0-2 Low battery voltage detected prior to
starting charge cycle
Battery voltage too low to charge. Check battery voltage and cable
connections.
Check battery condition.
Self clearing when condition has
been corrected.
E-0-0-3 Charge timeout
Charge timeout caused by battery
pack not reaching required voltage
within safe time limit.
Charge output reduced due to
high temperature. Charge at
lower temperature.
Check battery condition.
Replace damaged battery.
Check battery connections.
Battery pack deep discharge.
Disconnect battery pack for
30 seconds to clear fault when
condition has been corrected.
E-0-0-4 Defective battery Battery pack could not be trickle
charged up to the minimum voltage.
Check battery condition.
Replace damaged battery.
Check battery connections.
Disconnect battery pack for
30 seconds to clear fault when
condition has been corrected.
E-0-0-7 Amp hour limit exceeded Safety limit exceeded. Check battery condition.
Replace damaged battery.
Check battery connections.
Battery pack deep discharge.
High parasitic loads on battery
pack while charging.
Disconnect parasitic loads.
Disconnect battery pack for
30 seconds to clear fault when
condition has been corrected.