www.ti.com
Table 6-27. SPI Master Mode External Timing (Clock Phase = 1)
(1)(2)
SPI WHEN (SPIBRR + 1) IS EVEN OR SPI WHEN (SPIBRR + 1) IS ODD AND
SPIBRR = 0 OR 2 SPIBRR > 3
NO. UNIT
MIN MAX MIN MAX
1 t
c(SPC)M
Cycle time, SPICLK 4t
c(LCO)
128t
c(LCO)
5t
c(LCO)
127t
c(LCO)
ns
t
w(SPCH)M
Pulse duration, SPICLK high 0.5t
c(SPC)M
10 0.5t
c(SPC)M
0.5t
c(SPC)M
0.5t
c(LCO)
10 0.5t
c(SPC)M
0.5t
c(LCO)
(clock polarity = 0)
2
(3)
ns
t
w(SPCL)M
Pulse duration, SPICLK low 0.5t
c(SPC)M
10 0.5t
c(SPC)M
0.5t
c(SPC)M
0.5t
c(LCO)
10 0.5t
c(SPC)M
0.5t
c(LCO)
(clock polarity = 1)
t
w(SPCL)M
Pulse duration, SPICLK low 0.5t
c(SPC)M
10 0.5t
c(SPC)M
0.5t
c(SPC)M
+ 0.5t
c(LCO)
10 0.5t
c(SPC)M
+ 0.5t
c(LCO)
(clock polarity = 0)
3
(3)
ns
t
w(SPCH)M
Pulse duration, SPICLK high 0.5t
c(SPC)M
10 0.5t
c(SPC)M
0.5t
c(SPC)M
+ 0.5t
c(LCO)
10 0.5t
c(SPC)M
+ 0.5t
c(LCO)
(clock polarity = 1)
t
su(SIMO-SPCH)M
Setup time, SPISIMO data valid 0.5t
c(SPC)M
10 0.5t
c(SPC)M
10
before SPICLK high
(clock polarity = 0)
6
(3)
ns
t
su(SIMO-SPCL)M
Setup time, SPISIMO data valid 0.5t
c(SPC)M
10 0.5t
c(SPC)M
10
before SPICLK low
(clock polarity = 1)
t
v(SPCH-SIMO)M
Valid time, SPISIMO data valid after 0.5t
c(SPC)M
10 0.5t
c(SPC)M
10
SPICLK high (clock polarity = 0)
7
(3)
ns
t
v(SPCL-SIMO)M
Valid time, SPISIMO data valid after 0.5t
c(SPC)M
10 0.5t
c(SPC)M
10
SPICLK low (clock polarity = 1)
t
su(SOMI-SPCH)M
Setup time, SPISOMI before 0 0
SPICLK high (clock polarity = 0)
10
(3)
ns
t
su(SOMI-SPCL)M
Setup time, SPISOMI before 0 0
SPICLK low (clock polarity = 1)
t
v(SPCH-SOMI)M
Valid time, SPISOMI data valid after 0.25t
c(SPC)M
10 0.5t
c(SPC)M
10
SPICLK high (clock polarity = 0)
11
(3)
ns
t
v(SPCL-SOMI)M
Valid time, SPISOMI data valid after 0.25t
c(SPC)M
10 0.5t
c(SPC)M
10
SPICLK low (clock polarity = 1)
(1) The MASTER/SLAVE bit (SPICTL.2) is set and the CLOCK PHASE bit (SPICTL.3) is set.
(2) t
c(SPC)
= SPI clock cycle time = LSPCLK/4 or LSPCLK/(SPIBRR + 1)
t
c(LCO)
= LSPCLK cycle time
(3) The active edge of the SPICLK signal referenced is controlled by the CLOCK POLARITY bit (SPICCR.6).
NOTE: Internal clock prescalers must be adjusted such that the SPI clock speed is limited to the following SPI clock rate:
Master mode transmit: 20 MHz MAX. Master mode receive: 12.5 MHz MAX.
Slave mode transmit: 12.5 MHz MAX. Slave mode receive: 12.5 MHz MAX.
120 Electrical Specifications Copyright © 2001–2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): TMS320F2810 TMS320F2811 TMS320F2812 TMS320C2810 TMS320C2811 TMS320C2812

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments TMS320C2810 and is the answer not in the manual?

Texas Instruments TMS320C2810 Specifications

General IconGeneral
BrandTexas Instruments
ModelTMS320C2810
CategorySignal Processors
LanguageEnglish

Related product manuals