Configuration and Calibration
3-27
3.11.1 Init (init)
Through this option we can activate or deactivate the Animal-weigher/Check-weigher
option. It can be activated in print mode or in total mode and be deactivated with off.
If it is activated in PRINT mode, the process is started on pressing the key
(or
equivalent RS-232 or digital input command) and the indicator prints a ticket on ending. If the
TOTAL mode is chosen, the process is started on pressing the key
(or equivalent RS-
232 or digital input command) and totalized on ending.
3.11.2 Delay time (t_del)
It is the time the indicator will be waiting without weight readings once the process
activation signal is given (by keyboard, RS-232 command or digital input).
During this time the indicator displays the message . Its value is configurable
from 0.0 to 50.0 seconds. If the entered value is above 50.0 seconds the indicator will display
the error message and then will show the previous memorized value.
3.11.3 Weight readings time (t_acc)
It is the time the indicator will be gathering weight readings of the weight on the
scale.
During this time the indicator displays the message . Once the
gathering process is ended the indicator makes an average of all the weight readings obtained
during this time and displays it , with an ā€œAā€ on the left to indicate that the weight
displayed is an average of the weight readings gathering.
Its value is configurable from 0.0 to 50.0 seconds. If the entered value is above 50.0
seconds the indicator will display the error message and then will show the
previous memorized value.
3.11.4 Tiempo de muestra (t_dis)
It is the time the indicator will display the average of the weight readings gathering.
Its value is configurable from 0.0 to 50.0 seconds. If the entered value is above 50.0 seconds
the indicator will display the error message and then will show the previous
memorized value.
Err_top
Err_top
--acc--
A 2.150
Err_top
--del--