SERVICE 5-4 Manual 0-5085
OVER PRESSURE: Indicates that operating pressure
is set too high. The Error Indicator will not flash
when the pressure is above 95 PSI. This LED will
remain ON and the system will operate but pilot
starting and cut performance may be affected.
NOTE
When the unit is turned ON the cooling fans MOT
1-3 will remain OFF. (In earlier units MOT 1 will turn
ON for one (1) second and then turns OFF) The fans
will turn ON when a START signal (Torch Switch,
Remote Pendant switch, or CNC START) is active
and will remain ON for ten (10) minutes after the
START signal is removed. If an over temperature
condition occurs, the fans will continue to run while
the condition exists and for a ten (10) minute period
after the condition is cleared.