Specifications
21
Electrical Components
Current Draw (Amps)
at 12.5 Vdc
Resistance
(Ohms)
Glow Plug 7 to 8.3 1.5 ± 0.15
Fuel Solenoid:
Pull In
Hold In
18 to 36
0.49 to 0.6
0.3 to 0.7
22 to 26
High Speed Solenoid 3.3 3.8
Condenser Inlet Solenoid (15 watt) 1.2 10.4
Receiver Tank Pressure Solenoid (15 watt) 1.2 10.4
Purge Valve (15 watt) 1.2 10.4
Hot Gas Solenoid (18 watt) 1.44 8.68
Liquid Line Solenoids (15 watt) 1.2 10.4
Suction Line Solenoids (18 watts) 1.44 8.68
Starter Motor 90 to 105 (cranking)
Thermostat
Type Solid state THERMOGUARD V Thermostat
Range -20 to 80 F (-29 to 27 C)
Heat Lockout:
Continuous Run Operation
CYCLE-SENTRY Operation (Optional Equipment)
Electric Standby Operation (Optional Equipment)
High Speed Heat locked out below 15 ± 3 F (-9.4 ± 1.7 C)
All Heat locked out below 15 ± 3 F (-9.4 ± 1.7 C)
All Heat locked out below 15 ± 3 F (-9.4 ± 1.7 C)
Electric Standby
Electric Motor 7.5 hp, 230 V, 60 Hz
RPM 1765
Full Load Amps 21.2 (230), 10.6 (460)
Locked Rotor Amps 58
Power Requirements 230/3/60 30 Amp, Power Cord Size 10 (AWG) for 50, 8 for 75