2
Functional Description
Data System
Thermo Scientific TSQ Series Hardware Manual 47
Figure 33. LC/MS system with a TSQ Series mass spectrometer, an Accela Open Autosampler, and an Accela 600/1250 Pump
I
0
Oil Mist Filter
Main Power
Off
Electronics Vacuum
Qualified
Service
Personnel
Only
Operating Mode
Service Mode
Power In
Operating Mode
Service Mode
System Reset
Pump On
Vent Valve Closed
Ethernet Link OK
Ethernet
100 Base T
+ 30V Max
Start In
Refer to Manual
Forepump
V ~230 50/60 Hz, 5.0 A Max
V ~230 50/60 Hz, 15.0 A Max
On
AUX
AUX 2 POWER FUSEAUX 1INTERFACE 2INTERFACE 1TERMINAL SER1 LAN MODBUS BUZZER WASH
STATION
L
E
D
355 River Oaks Parkway
San Jose, CA, U.S.A
This device complies with FCC Rules, Part 15.
Operation is subject to the following conditions
(1) This device may not cause harmful interference,
and (2) This device must accept any interference
received, including interference that may cause
undesired operation.
This product is manufactured under, and covered
by, one or more of the following U.S. patents:
CAUTION
REFER ALL SERVICE
TO QUALIFIED
PERSONNEL ONLY.
DISCONNECT INPUT
POWER BEFORE
OPENING COVER.
RESERVED
RESERVED
GND
GND
INJECT HOLD
PUMP READY
GRAD. START
5V
USB
D-SUB25
Model: 1250 Pump
Serial No: 925000
DO NOT COVER
RS232
5,653,876 6,248,157 B1
Futher patent pending
DO NOT USE
TOGETHER
WITH
D-SUB25
!
!
EP 2107241A2
12345678
EN
61010 1
LINE
FUSE
100V 115V 230V 50/60 HZ
T2.0A T1.0A 220VA
!
STACK COOLER DW
TO 60157-63024
60157-63026
TO LCQ FLEET
TO LTQ/LXQ/MSQ
TO TSQ/EXACTIVE
TO PDA
TO MSQ/LTQ/LXQ
TO PUMP
60157-63024
TO A/S
PELTIER
THERMOSTAT
Input: 100V – 240V
2A 50/60 HZ
Output: 24V 4.5A
I
O
ETL LISTED
CONFORMS TO
UL STD 61010A-1
CERTIFIED TO
CAN/USA C22.2 STD NO. 61010-1
36V 4.16A
PAL
AUX
TO A/S
TO PUMP
TO 60157-63024
TO LCQ FLEET
TO LTQ/LXQ/MSQ
60157-63026
TO MSQ/LTQ/LXQ
TO TSQ/EXACTIVE
TO PDA
Accela Open Autosampler
interconnect cable
(contact closure)
Detector adapter cable
(contact closure)
TSQ Series
mass spectrometer
Connect to
autosampler
Connect to mass
spectrometer
Not used
Connect to
LC pump
Connect to
optional Accela
detector
Contact closure
cables
Accela
Open Autosampler
Forepump
RS232
communication
cable
Accela 600
or
Accela 1250
LC pump
Ethernet
switch
USB communication cable
Ethernet
communication
cables

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermo Scientific TSQ Quantum Access MAX and is the answer not in the manual?

Thermo Scientific TSQ Quantum Access MAX Specifications

General IconGeneral
BrandThermo Scientific
ModelTSQ Quantum Access MAX
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals