9-20
dummyheaddummyhead
STARTING SYSTEM
NEUTRAL SWITCH INSPECTION
INSPECTION
Remove the fuse/relay junction box (page 10-3).
Disconnect the neutral switch 2P connector [1] and
release the connector from the connector holder.
Attach the tester leads to the two terminals at the
neutral switch.
Continuity should exist at each position as follows:
SWITCH PUSHED
(Shift lever in "N")
Continuity
SWITCH RELEASED
(Shift lever in "F" or "R")
No continuity