28. SPECIFICATIONS
179
Distance measurement
Measuring method Coaxial phase-contrast measuring system
Signal source Red laser diode 690nm
Class 3R
(IEC60825-1 Ed. 2.0: 2007/FDA CDRH 21CFR Part1040.10 and
1040.11 (Complies with FDA performance standards for laser
products except for deviations pursuant to Laser Notice No.50, dated
July 26, 2001.))
(When target (reflector) is set to prism or reflective sheet, the output
is equivalent to Class 1)
Measuring range
*9
(Using the following reflective prism/reflective sheet target during
normal atmospheric conditions
*1
./ *2 is good atmospheric
conditions.)
360° Prism ATP1/ATP1S:
*2
1.3 to 1,000 m (3,280ft)
*3
Prism-5: 1.3 to 500m (1,640ft)
*7
Prism-2 X 1: 1.3 to 5,000m (16,400ft)
*7
(to 6,000m) (19,680ft)
*7
Prism-2 X 3: to 8,000 m (26,240ft)
*7
(10,000m) (32,800ft)
*7
Reflective sheet RS90N-K: 1.3 to 500m (1,640ft)
*4
Reflective sheet RS50N-K: 1.3 to 300m (980ft)
*4
Reflective sheet RS10N-K: 1.3 to 100m (320ft)
*4
Reflectorless (White) : 0.3 to 800m (2,620ft)
*5
(to 1,000m) (3,280ft)
*6
Prism (tracking)
*3
:1.3 to 1,000m (3,280ft)
Refrective sheet target (tracking)
*4
:1.3 to 350m (1,140ft)
Reflectorless (White) (tracking)
*5
:0.3 to 300m (980 ft)
Minimum display
Fine measurement:
0.0001m (0.001ft/ 1/16 inch)/0.001 m (0.005ft/ 1/8 inch)
Rapid
measurement:
0.001 m (0.005ft/ 1/8 inch)
Tracking measurement: 0.01 m (0.1ft/ 1/2 inch)
Maximum slope distance display (Except for tracking)
12,000.000m (39,370ft) (using prism or reflective sheet target)
1,200.000m (3,930ft) (Reflectorless)
Distance unit m/ft/inch (selectable)
Accuracy (D: measurement distance; Unit: mm) (Under normal atmospheric conditions
*1
)
*7, *9
(Using prism or using 360° Prism ATP1/ATP1S
*3
)
Fine measurement: (1.5 + 2 ppm X D) mm
Rapid measurement: (5 + 2 ppm X D) mm
(Using reflective sheet target)
*4
Fine measurement: (2 + 2 ppm X D) mm
Rapid measurement: (5 + 2 ppm X D) mm
(Reflectorless (White))
*5
Fine measurement:
(2 + 2ppm X D) mm (0.3 to 200m)
*8
(5 + 10ppm X D) mm (over 200 to 350m)
(10 + 10ppm X D) mm (over 350 to 1,000m)
Rapid measurement:
(6 + 2ppm X D) mm (0.3 to 200m)