28. SPECIFICATIONS
(8 + 10ppm X D) mm (over 200 to 350m)
(15 + 10ppm X D) mm (over 350 to 1,000m)
(ISO 17123-4 : 2001)
Measurement mode Fine measurement (single/repeat/average)/Rapid measurement
(single/repeat)/Tracking (selectable)
Measuring time (fastest time under good atmospheric conditions
*2
, no compensation,
EDM ALC at appropriate setting, slope distance)
Fine measurement: less than 1.5 sec + every 0.9 sec or less
Rapid measurement: less than 1.3 sec + every 0.6 sec or less
Tracking measurement: less than 1.3 sec + every 0.4 sec or less
Atmospheric correction
Temperature input range: - 30 to 60°C (in 0.1°C step)/ - 22 to 140°F (in 0.1°F step)
Pressure input range: 500 to 1,400 hPa (in 0.1hPa step)
375 to 1,050 mmHg (in 0.1mmHg step)
14.8 to 41.3 inchHg (in 0.01inchHg step)
ppm input range: -499 to 499 ppm (in 0.1 ppm step)
Prism constant correction -99 to 99 mm (in 0.1 mm step)
0mm fixed for reflectorless measurement
Earth curvature and refraction correction
No/Yes K=0.142/Yes K=0.20 (selectable)
Sea level correction No/Yes (selectable)
*1 : Slight haze, visibility about 20 km, sunny periods, weak scintillation.
*2 : No haze, visibility about 40 km, overcast, no scintillation.
*3 : Figures when both the elevation and depression angles of the laser beam are within 15° and
the instrument is facing the 360° Prism.
*4 : Figures when the laser beam strikes within 30° of the reflective sheet target.
*5 : Figures when using Kodak Gray Card White side (reflection factor 90%) and brightness level
is less than 5,000 lx.
*6 : Figures when using Kodak Gray Card White side (reflection factor 90%) and brightness level
is less than 500 lx.
*7 : Face the prism toward the instrument during the measurement with the distance at 10 m or
less.
*8 : Accuracy is (5 + 2 ppm X D) mm for distance range 0.3 to 0.66m.
*9 : Figures will change depending on the target reflection factor, weather conditions and location
conditions.
Auto Tracking
Measuring method Pulse laser transmitter and image detector with co-axial optics
Signal source (emitted beam) infrared laser diode (980nm)
Class 1
(IEC60825-1 Ed. 2.0: 2007/FDA CDRH 21 CFR Part 1040.10 and
1040.11 (Complies with FDA performance standards for laser
products except for deviations pursuant to Laser Notice No.50, dated
June 24, 2007.))
Viewing angle ± 45’
Measuring range V: Elevation angle 90° (when handle is attached: 70°),
Depression angle 41°
*11
Maximum Auto Tracking measurement range
*12
360° Prism ATP1/ATP1S: 2 to 600 m (1,960 ft)
*3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Topcon DS Series and is the answer not in the manual?

Topcon DS Series Specifications

General IconGeneral
BrandTopcon
ModelDS Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals