46
9. CONNECTING TO EXTERNAL DEVICES
Set "Comms mode" in the "Comms setup" tab to
"Bluetooth".
Changing communication settings during
Bluetooth communication will cancel the
connection.
The status bar icon cannot be tapped in
<Communication Setup>.
Do not change the setting’ (2) to (7) from the
factory setting, when performing Bluetooth
communication with a recommended data
collector.
Setting’ (4) to (7) are for an instrument using
GTS commands.
Items set and options (*: Factory setting)
(1) Comms mode : RS232C*/Bluetooth
(2) Check sum : yes/No*
(3) Controller : Remote/2 Way/2
Way+Remote*
(4) REC Type : REC-A *(newly measured
data is output)/REC-B
(displayed data is output)
(5) Terminate
: ETX*/ETX+CR/ETX+CR+LF
(6) Motor State : On (with track state
information)/Off*
(7) Ack mode
:On*/Off
Terminate
Select the option Off or On for carrige return (CR) and line feed when collecting measurement
data with a computer.
ACK mode
When communicating to an external device, the protocol for handshaking can omit the [ACK]
coming from the external device so data is not sent again.
On : Standard
Off : Omit the [ACK]