Specifications
68
Excavator Indicate System P/N: 1022461-01
Specifications
This chapter provides specifications for the MC-X1 Controller and GR-i3 Antenna.
MC-X1
Tabl e 2 lists the MC-X1 specifications.
Table 2. MC-X1 Specifications
General
Supply Voltage 9-32VDC
Supply Current 0.2A typical operating current; max. at 24VDC input power, no peripheral
equipment;
7.5A max. operating current
Electromagnetic
Compatibility
Applicable Standards
Emissions:
Applicable regulation: EN 13309:2010; ISO13766:2006; EN 55032:2012
Immunity:
Applicable regulation: EN 13309:2010; ISO 13766:2006; EN 301 489-1
Switched Output
Power
5A sensor/conditioned output power
Ports 1 ea. port RS232/Digital IO
2 ea. Ethernet
2 ea. CAN
Wireless WIFI 802.11abgn and BT 2.0/BLE 4.1
Environmental
Operating
Temperature
-40°C (-40°F) to +80°C (176°F)
Moisture Test Per SR-012 level 2: 240 hours at 96%RH
Ingress
Protection
IP67
Shock Test 25G 11 ms ½ sine wave 6X each axis
Salt Fog Test ASTM B117-03
Vibration Test 10-2000Hz Random, 7.7 Grms.