Dog-bone Sensor Mounting (Optional)
P/N 7010-0697
2-9
Figure 2-6. Bucket Sensor Mounting
Dog-bone Sensor Mounting
(Optional)
An alternative location for the bucket sensor is the dog-bone. This
location may offer additional protection compared to mounting the
sensor directly on the bucket. If possible, placing the sensor on the
inside of the dog-bone will provide additional protection. Mounting
the sensor on the dog-bone requires additional calibration steps.
NOTE
If using the dog-bone mounting option, worn joints
in the dog-bone linkage will cause decreased
accuracy.