Calibrating the Sensors
P/N 7010-0697
3-9
Calibrating the Sensors
Once the sensors are named (3DMC V7.06 and older only), assigned
to a machine element, and the orientation is selected, calibrate each
sensor using 3DMC. A sensor calibration can be performed at any
time.
Body Sensor Calibration
The body sensor calibration requires both the pitch and roll
calibrations. Perform both calibrations at the same time to ensure
accurate measurements.
Figure 3-6. Body Calibrations for Latitudinal Slope
The best practice is to perform the machine
calibrations as ordered in this manual. Performing
the calibrations out of order will not affect system
performance. The exception to this is when using a
dog-bone sensor. You must calibrate the stick
sensor before calibrating the dog-bone sensor.
Starting Position