AudibleAlarm
1
2
g288610
Figure264
1.Frontpowercenter2.Audiblealarm
Theaudiblealarmsoundstonotifytheoperatorwhenamachineproblemexists.
Electricalcurrentforthealarmisprovidedasanoutputfromtheslavecontroller.
Theaudiblealarmislocatedinthefrontpowercenterbehindtheoperatorseat
(Figure264).
Testing
1.MakesurekeyswitchisOFF .Removekeyfromkeyswitch.
2.Removepowercentercoverfromoperatorplatformtoaccessaudiblealarm
anddisconnectmachinewireharnessfromalarm.
IMPORTANT
Makesuretoobservepolarityonthealarmterminalswhentesting.
Damagetothealarmmayresultfromanimproperconnection.
1
2
3 4
g288611
Figure265
1.T opview
3.Positive(+)terminal
2.Bottomview
4.Negative(−)terminal
3.Correctlyconnect12VDCpowertotheterminalsasshown(Figure265).The
alarmshouldsound.Replacethealarmifnecessary.
4.Reconnectmachinewireharnesstoalarm.
5.Installandsecurepowercentercover.