CuttingDeck(PTO)OperatingProblems
ChecktheInfoCenterDisplayforanyoperatoradvisoriesorfaultsthatmay
appear.UsetheInfoCenterDisplayDiagnosticsfeaturetohelpidentifythe
problem(seeDIAGNOSTICSSCREENS(page6–22)).
Problem
PossibleCause
Theseatswitchorcircuitwiringisfaulty.
Ahydraulicprobleminthemowcircuitexists
(seeChapter5:HydraulicSystem(page5–1)).
Thecuttingdecksremainengaged,butshould
not,withnooperatorintheseat.
TheslaveTECisfaulty.
Thecuttingdeckpositionswitchorcircuit
wiringisfaulty.
Ahydraulicprobleminthemowcircuitexists
(seeChapter5:HydraulicSystem(page5–1)).
Cuttingdeckruns,butshouldnot,whenraised.
DecksshutoffwithPTOswitch.
TheslaveTECisfaulty.
Boththedeckpositionswitchorcircuitwiring
andPTOswitchorcircuitwiringarefaulty.
Cuttingdecksrun,butshouldnot,whenraised.
DecksdonotshutoffwiththePTOswitch.
Ahydraulicprobleminthemowcircuitexists
(seeChapter5:HydraulicSystem(page5–1)).
Boththecuttingdeckpositionswitchorcircuit
wiringandPTOswitchorcircuitwiringare
faulty.
Cuttingdecksrun,butshouldnot,when
loweredwithPTOswitchintheOFF
(disengage)position.
Ahydraulicprobleminthemowcircuitexists
(seeChapter5:HydraulicSystem(page5–1)).
ThePTOswitchorcircuitwiringisfaulty. Cuttingdecksrun,butshouldnot,when
loweredwithPTOswitchintheOFF
(disengage)position.
TheslaveTECisfaulty.
Onecuttingdeckdoesnotoperatewhen
loweredwiththePTOengaged.
CuttingdeckmanifoldsolenoidcoilPRVor
circuitwiringforaffecteddeckisfaulty.
Thecuttingdeckpositionswitchorcircuit
wiringisfaulty.
Ahydraulicprobleminthemowcircuitexists
(seeChapter5:HydraulicSystem(page5–1)).
Troubleshooting:Page3–12
Groundsmaster
®
5900&5910
16227SLRevB