Toshiba Tosvert VF-A5 - Page 104

Toshiba Tosvert VF-A5
157 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Stall
prevention,
current
limit,
overcurrent,
overvoltage,
load-side
short
circuit,
load-side
ground
fault,
undervoltage,
momentary
power
failure
(15ms
and
longer),
regeneration
Protective
functions
power
ride-through
control,
electronic
thermal
overload
protection,
armature
overcurrent
c:
during
start-up,
load-side
overcurrent
during
start-up,
dynamic
braking
resistor
.Q
~
overcurrent'overload,
heatsink
overheat,
emergency
stop,
<apen
output
phase>:
Note3)
e
Electronic
thermal
protection
Standard
motor/constant-torque
VF
motor
switching,
electronic
thermal
stall
prevention
a...
characteristics
operation
level
adjustment
Reset
Reset
when
1a
contact
point
is
"closed",
or
reset
by
panel.
Tripped
state
retention
and
clear
settings.
4-digit,
Displays
0.0
to
400Hz
and
OFF
status.
7-segment
Output
frequency/
While
running,
displays
stall
prevention,
overvoltage
limit,
overload,
power-source
LED
stop
dislpay
undervoltage,
DC
circuit
undervoltage,
and
executing
retry.
Parameters:
setting
error,
upper
limit,
lower
limit
Overcurrent,
overvoltage,
heatsink
overheat,
load-side
short
circuit,
load-side
ground
fault,
inverter
overload,
armature
overcurrent
during
start-up,
load-side
overcurrent
during
start-
Fault
causes
up,
(dynamic
braking
unit
overcurrent'overload),
(emergency
stop),
EEPROM
error,
RAM
error,
ROM
error,
communication
error,
(undervoltage),
(low
current),
(overtorque),
(open
i'a"
output
phase),
(motor
overload).
Items
in
parentheses
can
be
selected/deselected.
~
Terminal
input'output
status,
forward/reverse,
frequency
setting
value,
output
current,
DC
i:5
Monitor
functions
current,
output
voltage,
output
power,
torque
current,
cumulative
run
time.past
faults,
overload
ratio,
post-compensation
output
frequency
Selectable
units
Can
select
frequency
display
to
match
motor
speed,
line
speed,
etc.
Selection
of
display
of
display
current
in
amperes/%,
voltage
in
volts/%.
Edit
function
Automatic
editing
of
parameters
differing
from
standard
values.
Allows
for
easy
searching
of
changed
parameters.
Blind
function
Select
to
not
display
unneeded
parameter
groups.
User
settings
Saving
of
user
parameter
values
for
initialization
resetting
possible.
Parameters
can
be
initialization
easily
reset
to
user
difault
setting
values.
LED
Charge
.indicator
Indicates
that
main
circuit
capacitors
are
charged.
Fault
detection
signal
: Note4)
1 c
contact
output
(ac250V-2A-cos
rf>
""1,
ac250V-1
A-cos
rf>""
0.4,
DC30V-1
A)
"'
Low
speed/speed
reach
signal
Open-collector
outputs
(Max.
24Vdc,
Max.50mA,
output
impedance:
330)
(ii
outputs
:
Note
4)
c:
-~·
Upper/lower
limit
frequency
signal
"'
Open-collector
outputs
(Max.
24Vdc,
Max.
50mA,
output
impedance:
330)
~
outputs
:
Note
4)
8
Frequency
meter/ammeter
outputs
1
mAdc
full-scale
ammeter
or
7.5Vdc-1
mA
voltmeter
:
Note
5)
Pulse-train
frequency
output
Open-collector
output
(Max.
24Vdc,
Max.
50mA)
Communication
functions
RS232C
equipped
as
standard
(Connector:
modular
SP),
RS485,
TOSLINE-F10,
TOSLINE-
S20
are
optional.
"'
Service
environment
Indoor,
altitude
1
OOOm
of
less,
not
subject
to
direct
sunlight
of
corrosive/explosive
gases
c::
0
=
Ambient
temperature
-10
to
+40°C
(Max.
50°C
possible
when
cover
is
removed:
notes
8
and
9)
'6
c::
-25
to
+65°C
8
Storage
temperature
Q)
<.>
Relative
humidity
20
to
90%
(no
condensation
allowed)
-~
Q)
Vibration
5.9m/s
2
{0.6G}
or
less
(10
to
55Hz)
(according
to
JIS
C0911)
"'
Note
1)
In standard configuration on 30kW and smaller units, the control power inputs are connected to the
main circuit power source. These can be easily separated if necessary.
Note
2)
800Hz is possible with special modifications, but a de-rating of the output current raing is necessary.
Note
3) Optional.
Note
4)
Programmable ON/OFF output terminal signals. Can be allocated from 62 types of signals.
Note
5)
Programmable analog output terminal. Can be allocated from 14 types of signals.
Note
6}
The
11
contact input terminals (of which three are optional) are programmable contact input
terminals, and can be
allocated from 52 types of signals.
Note
7) Three holes can be opened for input main circuit wiring, output main circuit wiring, and control
circuit wiring, but the openings must be securely covered after wiring.
Note
8}
When the cover
is
removed, always install the unit
in
a panel
so
that charged sections
are
not
exposed.
22kW and larger units can handle
-10 to
50°C
without removal of the cover.
Note
9)
22kW and larger units have a large opening instead of a wiring cover, an there is
no
space for
bending externally-connected cables inside the unit. Use the optional wire opening cover when
the unit is not installed in a
panel.