(Note)
IE
SI::
Pl
in
Gr.P.-
settings: 0 : Coast-stop
: Decelerated stop
2 : Emergency
DC
injection braking stop
If
2
is
selected, also set the
DC
injection current
Id
b [ I
and
ESTOP
DC
injection time
IE
cl
bf:
I.
E658CS16
*
If
DC
braking is not required during normal stopping
when
IE
SI;
Pl= 2 (emergency
DC
injection
braking
stop)
is selected, set
the
DC
braking time
ldbl::
I to 0 .
Caution
The emergency stop command forcibly stop the motor with the inverter unit key operation
even
if
the
command
mode
is
not set
to
panel operation
mode.
This command cannot
be
prohibited with
the
command
mode
selection.
When
executed, the emergency stop will
be
regarded
as
a trip
and
will
be
recorded
as
a past fault.
7.4.7 Fault Reset
Remove
the
trip cause before resetting
an
inverter that
has
tripped due to a failure
or
other fault.
The
inverter will trip again if the cause
is
not removed.
Reset the tripped state with
one
of
the
following methods:
Reset
(1)
Turn off the power (until the
LED
display goes out) Note
1)
(2)
External signal (short circuit between control terminals RES-CC)
(3)
Panel
operation
Resetting with
the
panel
is
performed
by
the following process.
1.
Press
I STOP/RESET I
and
confirm that [ L ,-
is
displayed.
Note
1)
Refer
to
[,
,-
.P
,- .
It
,-
CL
I
(page
85).
2.
Press
I STOP/RESET I again,
and
if
the trip cause
has
been
removed, the inverter will
reset.
* For the following overload trips, the inverter cannot
be
reset with
an
external signal
or
with
the
panel
during
the
required cooling time.
IC:
L I,-, I : inverter overload
I
c:
L n
I;
I : motor overload
: dynamic braking resistor overload
The standard cooling time settings
are
as
follow:
IC:
L ;
,-,
I : Approx. 1 minute after trip
IC:
L n
I=
I : Approx. 5 minute after trip
IC:
L ,- : Approx. 30 seconds after trip
Caution
To
reset immediately
due
to
an
emergency, the power
can
be
turned off
to
reset
the
inverter,
but
if
this method
is
used
frequently, the inverter
or
motor
may
be
damaged.
- 49 -