EasyManua.ls Logo

Toshiba Tosvert VF-A5 - Page 126

Toshiba Tosvert VF-A5
157 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E6580516
,-
,-,
,_,
1
-
,-
1
-
(Protection
Parameters)
Function
Trtle
Adjustment
range
Resolution
Default
Page
Dynamic
braking
selection
(DBR)
Pb
I
0:
No
DBR
-
Depends
82
I
I
1:
With
DBR,
no
Olr
detection
on
inverter
I
I
I
2:
With
DBR,
and
Olr
detection
rating
I
~-----~------------------------
'"pt:;,:----::-
-----------------------------
----------
2
DBR
resistor
value
1.0-1000
0.10
L-------------------------
~---------r--
0~01=:-so-0--------------------
----------
:
DBR
capacity
Pb[P
I*
0.01kW
Overvoltage
stall
protection
OPSS
I
O:ON
-
0
82
I
I
I
1:0FF
I
DC
injection
starting
frequency
dbF
I
0-120
0.1/0.01
Hz
0.0
79,80,81
-----,-------------------------
---------J..--
-0,:1000/o.1.A-------------,Nateii
----------
--------
Other
:
DC
injection
current
db[
.
1%/A
0
than
0 :
DC
injection
time
dbl=
.
0.0-10.0
0.1
sec.
0.0
Forward/reverse
DC
injection
priority
db
SL
O:OFF
-
0
80
control
1:
ON
Motor
shaft
stationary
control
db
;,-,
O:OFF
-
0
81
1:
ON
Emergency
stop
selection
ESl=P
I
0:
Coast-stop
-
0
83
I
I
I
1:
Decelerated
stop
I
I
_
2
~-~9J~Le.9~i9~-~t9p
______________
I
--2--iE°STOP-DC-in]eciiontime
_____
---------.L--
----------
--------
Edbl=
I
.
0.0-10.0
0.1
sec.
0.1
I
Retry
selection
,-f=
,-1;:1
I
0:
no
retry
function
-
0
83
I
I
1-10:
1-101ime
I
-----~-------------------------
---------L.--
------------------------------
----------
--------
Other
:
Retry
time
setting
,-
f=
I=
I
.
0.0-10.0
0.1
sec.
1.0
I
I
than
o:
I
I
Regeneration
power
ride-through
I I r
I
O:OFF
-
0
84
UUI-
I
control
I
1:0N
I
-----,-------------------------
_________
,.
__
-0.0:::25:0----------------------
----------
--------
1
Ride-through
time
UuC
I=
:
0.1
sec.
2.0
.
Auto-restart
(motor
speed
search)
R.-St
I
I
O:OFF
(•1)
0
84
I
+
1:
On
momentary
power
failure
I
I
I
+2:
On
ST
make/break
(commercial
power
switching)
I
Motor
overload
protection
level
t
1-:,-
I
10-100%/A
(Note
1)
1%/A
100
77
I
OL
reduction
start-up
frequency
DLF
0-30
0.1/0.01
Hz
30.0
77
Motor
150%
overload
time
limit
OLI=
10-2400
10
sec.
600
77
OL
selection
r-11
r-1
0:
standard
UC-
I I
(•1)
-
0
78
+
1:
soft-stall
ON
+2:
OLMt
trip
OFF
Stall
protection
5c_
,-
I
O:ON
-
0
78
c_
'-
I
1:
OFF
--o--:s1a1Tprotectionle¥e1-iCtin--eri1--
_________
,.
__
------------------------------ ----------
--------
SCL
I : *
10~215%/A
(Note
1)
1%/A
150
:limit
level
adjustment)
I
I
Note
1)
Parameters with note "A" shown
in
the Adjustment Range and Resolution columns will be displayed
in
either percent or Amps depending on the setting of
dSP[
in
[,,-.ut= .
-120-

Table of Contents

Related product manuals