E6582175
F-79
6
6.22.2 Hit and stop control
382 : Hit and stop control
383 : Hit and stop control frequency
Refer to “Hit & Stop control: E6581873” for details.
6.23 Acceleration/deceleration suspend function
(Dwell function)
f349 : Acceleration/deceleration suspend
function
f350 : Acceleration suspend frequency
f351 : Acceleration suspend time
f352 : Deceleration suspend
frequency
f353 : Deceleration suspend time
[Parameter setting]
Title Function Adjustment range Setting value
f349 Acceleration/deceleration suspend function
0:Disabled
1:Parameter setting
2:Terminal input
0
f350 Acceleration suspend frequency
0.0-fh (Hz) 0.0
f351 Acceleration suspend time
0.0-10.0 (s) 0.0
f352 Deceleration suspend frequency
0.0-fh (Hz) 0.0
f353 Deceleration suspend time
0.0-10.0 (s)
0.0
Note1: The acceleration suspend frequency (f350) should not be set below the starting frequency (f240).
Note2: The deceleration suspend frequency (f352) should not be set below the stop frequency (f243).
Note3: If the output frequency is lowered by a stall prevention function, the acceleration suspend function may be
activated.
• Function
This function suspends acceleration and deceleration when starting and stopping during the transportation
of heavy load by temporarily running the motor at a constant speed according to the delay in braking. It
also prevents the occurrence of overcurrent at starting and slippage at stopping by fixing the timing with
brake.
There are two ways to suspend acceleration or deceleration: suspending it automatically by setting the
suspend frequency and time using parameters, and suspending it by means of a signal from an external
control device.

Table of Contents

Other manuals for Toshiba Tosvert VF-S15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba Tosvert VF-S15 and is the answer not in the manual?

Toshiba Tosvert VF-S15 Specifications

General IconGeneral
CategoryInverter
Control MethodV/f control, Sensorless vector control
Cooling MethodForced air cooling
ModelTosvert VF-S15
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
Communication OptionsModbus RTU
Overload Capacity150% for 1 minute
Braking UnitBuilt-in braking transistor
Output Voltage3-Phase, same as input voltage
Operating Temperature-10 to +50°C (14 to 122°F)
Storage Temperature-20 to 65°C (-4 to 149°F)
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m above sea level
Input Voltage3-Phase 200 to 240 VAC, 3-Phase 380 to 480 VAC
WeightVaries depending on model (e.g., 0.8 kg to 16 kg)