Toshiba Tosvert VF-S15 - Extended Parameters

Toshiba Tosvert VF-S15
394 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E6582175
K-4
11
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference

0007 Default setting - - 0: -
1: 50Hz default setting
2: 60Hz default setting
3: Default setting 1 (Initialization)
4: Trip record clear
5: Cumulative operation time clear
6: Initialization of type information
7: Save user setting parameters
8. Load user setting parameters
9. Cumulative fan operation time
record clears
10, 11: -
12: Number of starting clear
13: Default setting 2 (Complete
initialization)
0 4.3.2

0099 Checking the
region setting
* 5
- - 0: Start setup menu
1: Japan (read only)
2: North America (read only)
3: Asia (read only)
4: Europe (read only)
*1 4.4

0050 EASY key mode
selection
- - 0: Standard setting mode at power on
1: Easy setting mode at power on
2: Easy setting mode only
0 4.5

-
Extended parameter
starting at 100
--- - - 4.2.2

-
Extended parameter
starting at 200
--- --

-
Extended parameter
starting at 300
--- --

-
Extended parameter
starting at 400
--- --

-
Extended parameter
starting at 500
--- --

-
Extended parameter
starting at 600
--- --

-
Extended parameter
starting at 700
--- --

-
Extended parameter
starting at 800
--- --

-
Extended parameter
starting at 900
--- --

-
Extended parameter
starting at A
--- --

-
Extended parameter
starting at C
--- --

-
A
utomatic edit
function
- - - - - 4.3.1
*1: Default setting values vary depending on the setup menu setting. Refer to section 11.5.
*5: Set “0” to activate the setup menu. Refer to section 11.5 about setting contents selected in setup menu.