2.
The unidirectional link should be disconnected once being detected, and the ports shut down
by DLDP can be restored after the fiber pairs are correctly connected.
" Pgvyqtm"Fkcitco"
Figure 8-13 DLDP Application Example
" Eqphkiwtcvkqp"Rtqegfwtg"
Uvgr" Qrgtcvkqp" Fguetkrvkqp"
1 Enable DLDP globally. Required. On the Gvjgtpgv" QCO→FNFR→FNFR page,
configure DLDP State as enable under the Global Config
tab in device A and B.
2 Enable DLDP on the
specified ports.
Required. On the Gvjgtpgv" QCO→FNFR→FNFR page,
configure DLDP State as enable on Gigabit Ethernet ports
1/0/27 and 1/0/28 in the Port Config table in device A and
device B.
3 Configure Shut Mode. Required. On the Gvjgtpgv" QCO→FNFR→FNFR page,
configure the Shut Mode as auto under the Global Config
tab in device A and B.
4 Check the ports’ state.
Required. On the Gvjgtpgv"QCO→FNFR→FNFR page,
select ports 1/0/27 and 1/0/28 in the Port Config table and
click the Tgugv"button to bring them up.
The DLDP information of Gigabit Ethernet ports 1/0/27 and 1/0/28 is shown below:
126