7.6.3.7 Attribute 0x70, Accept Parameter
Accept Parameter saves the measuring system parameter into the non-volatile
memory (EEPROM).
With write access 0 all changed attributes are stored permanently and the
acceptance of changed values for the instance attributes
0x0C, Direction Counting Toggle
0x65, Total Measuring Range
0x66, Number of Revolutions - numerator and
0x67, Number of Revolutions - divisor
is performed.
Attr.-ID
0x70
Data type
USINT
Access
Set / Get
Lower limit
0
Upper limit
255
Default
0
Connection path, Packed EPATH with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x70
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #112