54
TK 61009-12-OP-EN
Supply Voltage
DC 10.5 V to 32 V.
The Maximum absorbed currents are:
• 2,2A DC @ 12Vdc, in printing operations;
• 180mA DC @ 12Vdc, in recording operations;
• 1,2A DC @ 24Vdc, in printing operations;
• 100mA DC @ 24Vdc, in recording operations;
• 10mA DC (for 12 and 24Vdc), in sleep mode.
Accuracy Class
The TouchLog is certified with 2 different accuracy levels depending on the
temperature range:
1. Class 1: From -30ºC to -25ºC and from +8ºC to +30ºC.
2. Class 0.5: From -25ºC to +8ºC.
Recording Interval
Selectable from 1 minute to 60 minutes in steps of 1 minute.
Recording Duration
Memory capacity is 8MB, sufficient to record for a full year the 6 inputs at a
15 minutes recording interval.
In a case of a recording interval lower than 5 minutes, the memory capacity
might be full before the complete year depending on the number of inputs.
Data Archiving
In order to satisfy the requirements of national legislation, data must be
retained in the TouchLog memory for at least one year (see above). The data
archiving process in the flash memory works according to the FIFO principle
(First in First Out), meaning new recordings automatically replace the oldest
recordings. The recordings can also be printed on tickets and kept in internal
storage. Be aware that records from the internal printer should be kept in a
clean dry place to ensure that they are readable after one year. Other
archiving methods include to transfer to a USB memory key or to do a
download via a PC. See “Exporting the Data to a USB Flash Drive,” p. 51
regarding Wintrac download and data export possibilities.
SSppeecciiffiiccaattiioonnss