TK 61009-12-OP-EN
55
Time Recording Error
The maximum error of the clock in duration of 1 week is < 1 minute.
Climatic Environment
Recording -30 °C to +70 °C
Printing -20 °C to +55 °C
Transport and storage unpowered -40 °C to +85 °C
TouchLog Trailer kit for indoor or outdoor use
TouchLog Truck kit for installation in vehicle cabin
Software Protection Class
The software verification level is IIIa according to standard EN12830:2018.
External Certificates
For in-cab installation: ATP-MUC 1096TS
For trailer installation: ATP-MUC 1097TS
EMC
IImmmmuunniittyy
Conforms with requirements of EN61000-4-3 and EN61000-4-2.
Tested for Radiated immunity electromagnetic HF –field (from 80 MHz to
2700Mhz), and Electro Static Discharges (up to +/- 4kV and +/- 8kV loaded
power by contact discharge and up to +/- 8kV loaded power by air discharge)
RRaaddiiaatteedd EEmmiissssiioonn
Conforms with requirements of EN61000-6-3.
Radiated field emission from 30 to 1000MHZ, TouchLog passed the standard
2004/104/EC.
Periodic Verification
In accordance with EN13486: 2001.
SSppeecciiffiiccaattiioonnss