DE35-ST Operating Instructions
D292469I 113
Eject Head Maintenance, Needle Replacement and Planarization.
Needle Replacement and Planarization: EJT, EJTN, EJM,
EJMN, EJA, EJAN
Required Tooling & Supplies:
● Planarization Kit [PLNZ-TOOL-17277]
o Tool rings [2607, 3359, 28477]
o Flat mirror [4359]
o Hex Allen key 0.035” [2976]
o Hex Allen key 0.050” [3703]
o Hex Allen key 0.0275” [6232]
o Grease [2359]
o ¼” Permanent Dot Sticker [111019]
● ¼ Inch Open Ended Wrench
● Foam Swabs
Note: Contact Customer Support if you have any questions about this procedure.
Links:
Eject Head Overview
Needle Replacement & Planarization of 0.75 inch diameter (small) Eject Heads
Needle Replacement & Planarization of 1.1, 1.5 and 2.0 inch diameter (large) Eject
Heads
General Mirror Use Tips:
● Use clean and pristine mirror only. No scratches, pits or cracks.
● Needles tips caught in scratches, pits or cracks will not meet planarity
requirements.
● Set tool rings and eject caps gently on mirror surface.
● Avoid sliding on the mirror surface at all times, especially with needles inserted.
● Insert needles and planarize them by gravity only.
● Excessive pushing on needles will pit and scratch mirror as well as break needle
tips.
● Tighten set screws very gently while needles are in contact with mirror.
● Fully tighten set screws after piston is lifted off mirror.