120 D292469I
Insertion of new needle(s) and planarization.
7. Place the eject head with the topside surface down (holes that the needle tip(s)
exits) on the mirror. Carefully insert the new needles into the brass piston in the
appropriate holes.
8. Gently tap the back end of the needle lightly to ensure the tip of the needle is
resting on the surface of the mirror.
Note: Be careful not to move or slide the eject head on the mirror when it is flipped
as it may damage the needles.
9. Be sure that all needles are resting on the mirror. Rotate mirror and eject head 90°
and remove mirror. Lightly tighten each set screw(s). Needles are very easy to break
if too much force is applied.
Place eject head on a mirror
surface.
Insert the needle(s) into the
hole
Gently tap the back end of the
needle lightly to ensure the top of
the needle is resting on the surface
of the mirror
with eject
head 90°