DE35-ST Operating Instructions
D292469I 99
Facet Inspection Cycle
1. TURN ON TAPE VACUUM.
2. ARM GO TO PICK POSITION.
3. GO DOWN TO PICK HEIGHT.
4. TURN ON PICKUP VACUUM.
5. NEEDLE SPEED = XXXX u/sec
6. LIFT NEEDLES = XXX u
7. WAIT N.NNN SECS FOR DIE TO LIFT.
8. LIFT TO SEARCH HEIGHT AT XXXX u/sec.
9. GO UP TO TRAVERSE HEIGHT.
10. TURN OFF TAPE VACUUM.
11. RETRACT NEEDLES.
12. START UNDERSIDE INSPECTION IF ACTIVE.
13. ARM GO TO FACET INSPECT POSITION.
14. GO DOWN TO FACET INSPECT HEIGHT.
15. TURN ON INSPECT POSITION VACUUM.
16. TURN OFF PICKUP VACUUM.
17. PURGE PICKUP X.XXX secs.
18. GO UP TO TRAVERSE HEIGHT
19. PERFORM DIE FACET INSPECTION
20. FOOTPEDAL ROTATES, GRADE KEY ACCEPTS, KEY 0 REJECTS.
Die rotates when foot pedal or step key is pressed.
The toggle (+) key has two functions: shifting the camera display in the x-
axis (left or right) or to rotate the spindle manually 0 to 360 degrees. The
controls on the Remote Operator Control will operate these functions.
21. GO DOWN TO FACET INSPECT HEIGHT.
22. TURN ON PICKUP VACUUM.
23. TURN OFF INSPECT POSITION VACUUM.
24. GO TO TRAVERSE HEIGHT.
25. GO TO TRAY POSITION.
26. GO DOWN TO PLACE HEIGHT.
27. TURN OFF PICKUP VACUUM.