DE35-ST Operating Instructions
D292469I 85
9. ARM GO TO DIE INVERTER CLEARANCE POS.
The Pickup Arm will go to the Inverter Clearance Position. This is defaulted to
the right of the Inverter Assembly. This position can be adjusted by using the
Left/Right Arrow keys to move the X Axis Pickup Head as necessary. This
position is provided to ensure that the Pickup Head is clear of the Inverter during
the rotation step.
10. DIE INVERTER TO PICKUP POSITION
The Die Inverter Pickup Arm will rotate 180 degrees to bring the Inverter Pickup
Tip into contact with the previously placed die on the Inverter Flexure.
11. DIE INVERTER PICKUP VAC ON + DELAY
The Inverter Pickup Vacuum will turn ON. This is necessary to achieve proper die
transfer. There is a small delay that is not programmable.
12. DIE INVERTER FLEXURE VAC OFF + DELAY
The Inverter Flexure Tip Vacuum will turn OFF. This is necessary to achieve
proper die transfer. There is a small delay that is not programmable.
13. DIE INVERTER TO NORMAL POSITION
The Die Inverter Pickup arm will rotate back 180 degrees to the normal position.
14. ARM GO TO DIE INVERTER PICK POSITION
The pickup arm will move to position the pickup tip directly above the center of
the Inverter pickup position (a Pick Tip is installed into the arm and is used for
this position). The Left/Right Arrow keys can be used to move the X Axis Pickup
Head as necessary.
15. GO DOWN TO DIE INVERTER PRE-PICK HEIGHT
The Pickup Arm Z will move down to the Pre-Pick Height. The Up/Down keys can
be used to move the Z Axis as necessary. This position is provided to allow the
Operator to make fine X adjustments to the Inverter pickup/Die position without
the die coming in contact with the Inverter Tip. This height can be adjusted to be
the same as the Inverter Pick Height if desired.
16. GO DOWN TO DIE INVERTER PICK HEIGHT
The Pickup Arm Z will move down to the Pick Height. The Up/Down keys can be
used to move the Z Axis as necessary. The Left/Right Arrow keys can also be
used to make adjustments to the X position of the Pickup Tip. This position is
provided to pick up the die from the Inverter Pick Tip.
17. TURN ON PICKUP VACUUM
The Pickup Tip Vacuum will turn ON.