EasyManuals Logo

Vacon NX User Manual

Vacon NX
239 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #182 background imageLoading...
Page #182 background image
11
vacon • 180 Non-regenerative front end
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
11.5 Power ratings
Table 70. VACON
®
NXN Liquid-Cooled non regenerative front-end, DC bus voltage 465-800 VDC
AC drive type
AC current DC power
Power
loss
c/a/T*)
[kW]
Chassis
Thermal
I
th
[A]
Rated
I
L
[A]
Rated
I
H
[A]
400
VAC
mains
I
th
[kW]
500
VAC
mains
I
th
[kW]
400
VAC
mains
I
L
[kW]
500
VAC
mains
I
L
[kW]
NXN20006A0T0 2000 1818 1333 1282 1605 1165 1458 5.7/0.5/6.2 CH60
Table 71. VACON
®
NXN Liquid-Cooled non regenerative front-end, DC bus voltage 640-1100 VDC
AC drive type
AC current DC power
Power
loss
c/a/T*)
[kW]
Chassis
Thermal
I
th
[A]
Rated
I
L
[A]
Rated
I
H
[A]
525
VAC
mains
I
th
[kW]
690
VAC
mains
I
th
[kW]
525
VAC
mains
I
L
[kW]
690
VAC
mains
I
L
[kW]
NXN20006A0T0 2000 1818 1333 1685 2336 1531 2014 5.7/0.5/6.2 CH60

Table of Contents

Other manuals for Vacon NX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon NX and is the answer not in the manual?

Vacon NX Specifications

General IconGeneral
Product TypeAC Drive
Control MethodScalar Control
EnclosureIP00, IP21
CommunicationEthernet
SafetySTO (Safe Torque Off)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Ambient Temperature Range-10°C to +50°C (with derating above +40°C)
Cooling MethodAir-cooled, Liquid-cooled

Related product manuals