Technical data vacon • 35
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
4
Liquid cooling
Allowed cooling agents
Drinking water (see specification on page 49).
Water-glycol mixture.
See derating specifications, Chapter 5.3.
Volume See page 51.
Temperature of cooling
agent
0…35 °C input (I
th
); 35…55 ºC: derating required,
see Chapter 5.3.
Max. temperature rise during circulation max. 5 °C
No condensation allowed. See Chapter 5.2.1.
Cooling agent flow rates See Table 15.
System max. working
pressure
6 bar
System max. peak
pressure
30 bar
Pressure loss (at nom.
flow)
Varies according to size. See Table 17.
Table 13. Technical data

Table of Contents

Other manuals for Vacon NX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon NX and is the answer not in the manual?

Vacon NX Specifications

General IconGeneral
Product TypeAC Drive
Control MethodScalar Control
EnclosureIP00, IP21
CommunicationEthernet
SafetySTO (Safe Torque Off)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Ambient Temperature Range-10°C to +50°C (with derating above +40°C)
Cooling MethodAir-cooled, Liquid-cooled