Chapter 4 _________________________________________________________________ Operation
VAISALA ________________________________________________________________________ 71
Command Description
CHEC Displays average signal
CAL Calibrator_frequency
Calibration
CLRS Clears precipitation sums
ACAL Analog output calibration
TIME hh mm ss
Sets/displays system time
DATE yyyy mm dd
Sets/displays system date
BAUD rate par
Baud rate setting
(Rate 300, 1200, 4800, 9600)
(Par E(7E1) or N(8N1)
AN channel
Analog channel
(0,1,3,8 ... 15 or ANALOG ID)
DAC data
(Without DATA = SWEEP)
RESET Hardware reset by watchdog
WHIS Present weather history
WSET PRW reference values
DRY ON Sets DRD dry offset
WET ON Sets DRD wet scale
BLSC Sets/Displays background luminance scale
MES Command
After opening the line for operator commands (see section
Entering/Exiting the Command Mode on page 61), a data message can
be displayed using the MES command. There are eight messages
available for different uses and they numbered from 0 to 7. Refer to
section Message Types on page 63 for message type descriptions.
The command format is the following:
MES Message_number
with a valid range from 0 to 7. For example, when choosing the data
message number 2, type
MES 2
AMES Command
The AMES command defines the message, which the FD12P
transmits as the automatic message or as the default polled message.
Messages can also be displayed by the MES command, described in
MES Command on page 71.