Chapter 4 _________________________________________________________________ Operation
VAISALA ________________________________________________________________________ 79
System Configuration Commands
Table 20 below lists the commands that can be used to display system
parameters and to edit current system configuration.
Table 20 Commands for Displaying System Parameters and
Editing the Current System Configuration
Command Description
PAR Parameter message
CONF password
Update configuration
BAUD rate par Set baud rate (rate 300,1200,2400,4800,9600)
Par E (7E1), N (8N1)
BLSC Set/display background luminance scale
PAR Command
The current system parameters can be displayed by using the PAR, the
System Parameters, command.
When you type
PAR
the system output is shown on the next page.
SYSTEM PARAMETERS
VAISALA FD12P V 1.83 1999-11-19 SN: 46401
ID STRING:
AUTOMATIC MESSAGE 2 INTERVAL 15
ALARM LIMIT 1 0
ALARM LIMIT 2 0
OFFSET REF 130.50
CLEAN REFERENCIES
TRANSMITTER 8.9 RECEIVER 1769
CONTAMINATION WARNING LIMITS
TRANSMITTER 1.5 RECEIVER 200
CONTAMINATION ALARM LIMITS
TRANSMITTER 5.0 RECEIVER 500
SIGNAL SCALE 1 1.485 SCALE 0 0.000
TE OFFSET 58.5
TS SCALE 1 0.058 SCALE 0 -58.969
ANALOG VISIBILITY MAX 20000 MIN 10
LINEAR MODE
ANALOG OUTPUT SCALE 1 0.143 SCALE 0 713.00