Chapter 4 _________________________________________________________________ Operation
VAISALA ________________________________________________________________________ 73
Weather Related Commands
To display or set the weather analysis parameters and results, use the
commands listed in Table 19 below.
Table 19 Commands for Displaying or Setting Weather
Analysis Parameters
Command Parameters and Results
WPAR Weather parameter message
WSET Prw reference values
PRW Present weather message
CLRS Clear precipitation sums
WHIS Present weather history
WPAR Command
Use the WPAR command to display the present weather analysis
parameters. Typing WPAR ↵ displays the following output:
WEATHER PARAMETERS
PRECIPITATION LIMIT 40
WEATHER UPDATE DELAY 6
HAZE LIMIT 9000
RAIN INTENSITY SCALE 0.80
VIOLENT RAIN LIMIT 50
HEAVY RAIN LIMIT 8.0
LIGHT RAIN LIMIT 2.0
DRIZZLE LIMIT 15
HEAVY DRIZZLE LIMIT 30
LIGHT DRIZZLE LIMIT 3
WARM LIMIT 8.0
SNOW LIMIT 5.0
HEAVY SNOW LIMIT 600
LIGHT SNOW LIMIT 1200
SNOW PELLETS LIMIT 30
SNOW GRAINS LIMIT 20
ICE CRYSTALS LIMIT 40
HAIL LIMIT 300
DRD SCALE 1.5
DRD DRY OFFSET 900.0
DRD WET SCALE 0.0016
WSET Command
The WSET command is used to modify the present weather analysis
parameters.
The command asks for one parameter at a time, showing the
parameter name and the current setting. Accept the current value by
pressing ENTER. You can give a new value by typing the value
before pressing ENTER.