The following types are displayed in this log:
l Zones
– Alarm
– Panic
l System Events
– Confirmed Alarm
– User Duress
– XBus Panic
– User Panic
– RPA Panic
17.8 Users
The following table shows the maximum number of users, user profiles and user devices for the panel:
Maximum No. SPC4xxx SPC5xxx SPC6xxx
Users 100 500 2500
User Profiles 100 100 100
User Profiles per User 5 5 5
PACE Devices 32 250 250
SMS IDs 32 50 100
Web Passwords 32 50 100
RF Fobs 32 50 100
MDT Devices 32 32 32
WARNING: If upgrading from a firmware version prior to version 3.3, note the following:
- The Engineer web password, if configured, is deleted and must be reentered after upgrade.
- All existing users will be assigned to new user profiles corresponding to their previous user
access levels. If max. number of user profiles is exceeded, no profile is assigned (see
Adding/Editing User Profiles on page199). Review all user configuration after a firmware upgrade.
- The default Engineer ID is changed from 513 to 9999.
17.8.1 Adding/Editing a User
To add or edit a user:
1. Select Users>Users.
A list of configured users is displayed.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2018 196 A6V10276959-d
11.2018

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPCA210.100 and is the answer not in the manual?

Vanderbilt SPCA210.100 Specifications

General IconGeneral
BrandVanderbilt
ModelSPCA210.100
CategoryPower Supply
LanguageEnglish

Related product manuals