Vanderbilt SPCA210.100 - Configuration Requirements for PD 6662:2010 Conformance

Vanderbilt SPCA210.100
402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
See Zone types on page379 and Zone attributes on page384.
WARNING: Your attention is drawn to the fact that by allowing this method of unsetting, if an
intruder succeeds in forcing the initial entry door, the police will not be called, regardless of the
intruder’s further progress through the premises.
This method of unsetting the intruder alarm system might be unacceptable to your insurers.
6.4.6 Unsetting in conjunction with an alarm receiving centre (ARC)
Compliance by SPC using third party ARC software. Indication external to the building must be
provided by means of a timed buzzer/strobe, etc., that will operate on a system unset for a timed
period, for example, 30 seconds.
See Timers on page117.
3.5.4 Configuration requirements for PD 6662:2010 conformance
Recommendations for the recording of remotely notified alarm conditions (BS 8243:2010 -
Annex G.1 and G.2)
Alarm conditions can be categorised for analysis in accordance with Annex G if the SPC system is
configured so that the entry timer is less than 30 seconds, and the dialer delay is set to 30 seconds.
See the following sections:
l Areas on page121
l Adding/Editing an area on page270
l Timers on page117
Requirements for systems using dedicated alarm paths (BS EN 50136-1-2, 1998)
The SPC system should be configured to do an automated test call to the ARC.
The SPC system should be configured with a 'Fail to Communicate‘output.
See the following section:
l Adding/Editing an ARC using SIA or CID on page324
Requirements for equipment used in systems with digital communicators using PSTN (BS EN
50136-2-2, 1998)
Fault Output
The SPC system should be configured with a 'Fail to Communicate‘output.
See the following sections:
l Outputs on page152 (Keypad)
l Configuring controller inputs and outputs on page229 (Browser)
l Adding/Editing an ARC using SIA or CID on page324
Retransmission Attempts
Retransmission attempts (Dial Attempts) are configured in this manual:
l Adding/Editing an ARC using SIA or CID on page324
l Editing EDP settings on page333
A minimum of 1 and a maximum of 12 retransmissions are allowed.
Intrusion and hold-up - System design (DD CLC TS 50131-7, 2008)
Setting and unsetting
SPC system is configurable in such a way that the setting is completed by 'Final Exit'.
It is possible to configure the SPC so that a WD (Warning Device) is activated momentarily on setting.
SPC4xxx/5xxx/6xxx Installation & Configuration Manual Directives and standards
© Vanderbilt 2018 26 A6V10276959-d