Area Areas to which the zone is assigned.
LED When enabled, the LED will come on when the PIR is activated.
PIR Sensor Pulses Filter 1 Pulse Count – 1 activation will cause an alarm
2 Pulse Count– 2 activations will cause an alarm
3 Pulse Count– 3 activations will cause an alarm
Time Filter Disabled – Any activation will cause an alarm, in particular, the
activation does not need to be present for a pulse duration.
Pet Immunity Filter When enabled, will cause the PIR to ignore the motion caused by small animals.
PIR Sensitivity The PIR has 5 sensitivity settings. Select the lowest sensitivity when the
background light levels are changeable.
Magnetic contact
To program the attributes for a magnetic contact:
1. Select Configuration > Hardware > Wireless Settings.
2. Click the Edit button beside the desired magnetic contact.
3. Program the attributes.
Programmable attributes for Magnetic contact
Sensor The number of the sensor as enrolled on the system (1 = first, 2 = second, etc).
Description Text description of the sensor.
Sensor Type The type of wireless sensor detected (e.g. magnetic contact, PIR).
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2018 223 A6V10276959-d
11.2018

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPCA210.100 and is the answer not in the manual?

Vanderbilt SPCA210.100 Specifications

General IconGeneral
BrandVanderbilt
ModelSPCA210.100
CategoryPower Supply
LanguageEnglish

Related product manuals