Timer Description Default
General Settings
RF Output Time
RF OUTPUT
The time that the RF output will remain active on the system. (0–999 seconds) 0sec.
Time Sync Limit
TIME SYNC
LIMIT
Time limit within which time synchronization will not take place. Time
synchronization only takes place if system time and update time are outside this
limit. (0–300 seconds)
0sec.
Link Timeout
LINK TIMEOUT
Timeout for Ethernet link fault. (0–250 seconds; 0=Disabled) 0sec.
Camera Offline
CAMERA
OFFLINE
Time for camera to go offline. (10–9999 seconds) 10sec.
Frequent
FREQUENT
This attribute only applies to remote services. The number of hours within which a
zone must open if the zone is programmed with the Frequent attribute. (1–9999
hours)
336h (2
weeks)
Duress silent Time when duress will remain silent and not restorable from keypad. (0–999
minutes)
0min.
Holdup/panic
silent
Number of minutes that a holdup/panic will remain silent and cannot be restored
from the keypad. (0–999 minutes)
0min.
Default times are dependent upon the Engineer configuration. The default times denoted may or may
not be allowable and is dependent on the configuration by the engineer.
Valid settings/ranges may be dependent on the security grade specified under Configuration >
System > Standards.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2018 265 A6V10276959-d
11.2018