Installation, Operating & Maintenance Instructions
Series 615 DN 40 (I.D. 1½”), DeviceNet
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
603476EA
2013-07-25
65/102
Command
Service Code
Class ID
Instance ID
Attribute ID
Service
data length
(number of
bytes)
Service
data field
Description
EXCEPTION DETAIL
ALARM
EXCEPTION DETAIL
WARNING
Get
14
48
1
13 (alarm)
15
14 (warning)
Table with EXCEPTION DETAIL ALARM resp. EXCEPTION DETAIL WARNING bits.
0 OK
1 Exception / Failure / Error (except for detail size bytes)
Data
Component
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
PCV Common
Exception Detail
Size
0
0
0
0
0
0
1
0
PCV Common
Exception Detail
Byte #0
0
0
0
0
0
0
0
0
PCV Common
Exception Detail
Byte #1
0
0
0
0
0
0
0
0
PCV Device
Exception Detail
Size
0
0
0
0
0
1
0
0
PCV Device
Exception Detail
Byte #0
0
0
0
0
0
0
0
0
PCV Device
Exception Detail
Byte #1
0
0
0
0
0
0
0
0
PCV Device
Exception Detail
Byte #2
0
0
0
0
0
0
0
0
PCV Device
Exception Detail
Byte #3
0
0
0
0
0
0
0
0
Manufacturer
Exception Detail
Size
0
0
0
0
0
1
1
0
Manufacturer
Exception Detail
Byte #1
Reserved
Reserved
Isolation
valve
position
failure
Sensor ratio
exceeded
PFO not
ready
Compressed
air failure
Learn data
set
invalid
Service
request
Manufacturer
Exception Detail
Byte #2
Reserved
Reserved
Reserved
Reserved
Reserved
ADC not
responding
Reserved
Reserved
Manufacturer
Exception Detail
Byte #3
Reserved
Reserved
Reserved
Wrong
Controller
Mode
Wrong
Access
Mode
ZERO
disabled
Optional
hardware
missing
No sensor
Manufacturer
Exception Detail
Byte #4
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
PFO off
Simulation
active
Manufacturer
Exception Detail
Byte #5
Reserved
Reserved
Reserved
Reserved
E40
1)
E22
1)
E21
1)
E20
1)
Manufacturer
Exception Detail
Byte #6
Reserved
Reserved
Reserved
Valve power
OFF or
internal
com. error
Setpoint
invalid
(safe
state)
IO data
missing
(safe state)
Setpoint
type invalid
(safe state)
Control
mode
invalid
(safe state)
1) Refer to «Trouble shooting» for details on these fatal errors.