EasyManua.ls Logo

VAT 615 Series

VAT 615 Series
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation, Operating & Maintenance Instructions
Series 615 DN 40 (I.D. 1½”), DeviceNet
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
603476EA
2013-07-25
59/102
4.6.1 Assembly describtion
Instance
ID
Type
Composition
1)
Start
Byte
Byte
Length
Service
data
length
(number
of bytes
Data
Type
1
Input
PRESSURE
0
2
2
signed integer
2
Input
EXCEPTION STATUS
PRESSURE
0
1
1
2
3
signed integer
3
Input
EXCEPTION STATUS
PRESSURE
POSITION
0
1
3
1
2
2
5
signed integer
4
Input
EXCEPTION STATUS
PRESSURE
PRESSURE / POSITION SETPOINT
2)
0
1
3
1
2
2
5
signed integer
5
Input
EXCEPTION STATUS
PRESSURE
PRESSURE / POSITION SETPOINT
2)
POSITION
0
1
3
5
1
2
2
2
7
signed integer
6
Input
EXCEPTION STATUS
PRESSURE
PRESSURE / POSITION SETPOINT
CONTROL MODE
POSITION
0
1
3
5
6
1
2
2
1
2
8
signed integer
7
Output
PRESSURE / POSITION SETPOINT
2)
SETPOINT TYPE
0
2
2
2
4
signed integer
8
Output
CONTROL MODE
PRESSURE / POSITION SETPOINT
2)
SETPOINT TYPE
0
1
3
1
2
2
5
signed integer
10
Input
EXCEPTION STATUS
0
1
1
signed integer
11
Input
EXCEPTION STATUS
PRESSURE
POSITION
VALVE CLOSED / OPEN CHECK
0
1
3
5
1
2
2
1
6
signed integer
17
Input
FP-PRESSURE
0
4
4
floating point
18
Input
EXCEPTION STATUS
FP-PRESSURE
0
1
1
4
5
floating point
19
Input
EXCEPTION STATUS
FP-PRESSURE
FP-POSITION
0
1
5
1
4
4
9
floating point
20
Input
EXCEPTION STATUS
FP-PRESSURE
FP-PRESSURE / POSITION SETPOINT
2)
0
1
5
1
4
4
9
floating point
21
Input
EXCEPTION STATUS
FP-PRESSURE
FP-PRESSURE / POSITION SETPOINT
2)
FP-POSITION
0
1
5
9
1
4
4
4
13
floating point
22
Input
EXCEPTION STATUS
FP-PRESSURE
FP-PRESSURE / POSITION SETPOINT
2)
CONTROL MODE
FP-POSITION
0
1
5
9
10
1
4
4
1
4
14
floating point
23
Output
FP-PRESSURE / POSITION SETPOINT
2)
SETPOINT TYPE
0
4
4
2
6
floating point
24
Output
CONTROL MODE
FP-PRESSURE / POSITION SETPOINT
2)
SETPOINT TYPE
0
1
5
1
4
2
7
floating point

Table of Contents