EasyManua.ls Logo

VAT 615 Series

VAT 615 Series
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation, Operating & Maintenance Instructions
Series 615 DN 40 (I.D. 1½”), DeviceNet
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
603476EA
2013-07-25
82/102
Description
Required tool
Replace o-rings at plate
14. Push in the o-ring equally around the plate
into o-ring groove
15. Plate with equal mounted o-ring
Assemble and adjust
plate
16. Place the plate on the shaft in the valve
body
Assemble and adjust plate
17. Tighten plate screws to block.
18. Loosen the plate screws a quarter turn
counter clockwise.
Fact: Plate is now movable on shaft and ready
to sliding into valve seat. Proceed with step 19.
Allen Wrench
3mm
19. Connect electrical POWER connection at
valve
Attention!
Valve does synchronize automatically
and moves the plate into sit of valve
body (close position).
20. Disconnect electrical POWER connection
Attention!
Keep fingers out of the valve
opening during plate movement!