7.4 Installation with 1 actuator – solution D
The actuator is placed at one end of the CANBus network.
This installation scheme is valid for systems with:
up to 3 command stations and 1 engine with mechanical throttle, mechanical gearbox, with/without trim (or flap);
up to 3 command stations and 1or 2 engines with electronic throttle (voltage or CANBus), mechanical gearbox, with/
without trim (or flap);
up to 3 command stations and 1 or 2 engines with electronic throttle (voltage or CANBus), solenoid driven gearbox,
with/without trim (or flap);
Code: DTCANxx
JP19: ON (end-line)
JP14: OFF (address)
Actuator
Data transmission cable
Command station 2 Command station 3Command station 1