64 030624.13
vetus® Electronic engine remote control
12 Programming of actuators for installations with electronic engine
and mechanical gearbox
Systems components involved: push-pull cables, actuator
In this chapter it will be presented how to program the actuator, in order to obtain the correct strokes of gearboxes. De-
pending if the boat is with 1 or 2 propulsion systems, the actuator looks according one of the pictures here below:
You must program either 3 or 6 positions and consequently 3 or 6 parameters: 3 for per each gearbox, according to the
parameters of the above table.
Parameter
Value on
display
Function
Gearbox 1
(right)
0L Gearbox Reverse
0F Gearbox Neutral
0H Gearbox Forward
Gearbox 2
(left)
1L Gearbox Reverse
1F Gearbox Neutral
1H Gearbox Forward
Actuators are delivered from factory with Forward, Reverse and Neutral positions coincident in the Neutral position.
Therefore the installer must do the correct setting the stroke, in order to start-up correctly the system.
0L
0F
0H
1L
0L
0F
0H1H
1F
Gearbox
Left gearbox Right gearbox
Push Pull
Push Pull
Push Pull