EasyManua.ls Logo

Vetus EC3 - Specific Parameters

Vetus EC3
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
030624.13 63
vetus® Electronic engine remote control
System with mechanical throttle and mechanical gearbox
UL 0L
0F
0HUH
Gearbox
Throttle
Push Pull
Push Pull
Problem Solution
The gearbox push-pull cable positions
are inverted (forward and backward po-
sitions are inverted) while the throttle
push-pull cable works correctly
Set A0=3
The gearbox is working correctly while
the throttle push-pull cable positions
are inverted (min and max throttle po-
sitions are inverted)
Set A0=1
Both gear or throttle push-pull cables
positions are inverted
Set A0=2
11.3 Specific parameters
Display
code
Description Values
Factory
value
Value shown on dis-
play (factory value)
Note
A0
Push-pull cable movement direc-
tion
1 .. 4 4 04
dI
Delay before disengaging the
gearbox
0 .. 9.9 s 0.0 s 00
dA Delay on the throttle 0 .. 9.9 s 0.0 s 00
PP Proportional coefficient 0 .. 99 40 40 These para-
meters must not
be modified
PI Integral coefficient 0 .. 99 0 00
CC To be used for the check-up of the internal CANBus communication
The following examples show how to operate in case there is not the exact correspondence between the command lever
and the actuator.