Fast Tissues can be adjusted between -15% to +40%. The effect of the fast safety
setting reduces linearly from Fast to Mid range tissues.
Mid range Tissues can be adjusted between -15% to +40%. The effect of the Mid
setting reduces linearly from both mid range to fast, and from mid range to slow.
Slow tissues can be adjusted between -15% to +40%. The effect of the Slow setting
reduces linearly from slow to mid range.
Note: No less than a total of -20% across all tissue can be set.
To achieve the same setting for all tissues use the same percentage setting for Fast,
Mid and Slow.
Custom settings allow precise decompression matching to users known requirements
or expectation for the next planned dive.
Mid range tissue adjustment is an extra feature compared to standard gradient factor
adjustments. From stochastic dive data, Mid range tissues appear to require longer
decompression after prolonged bottom time and/or extreme depths. VGM has a built
in system for adjusting this, but the diver may wish to adjust the setting manually as
well.
Use Diveplan to check settings for next dive. Fine tuning of Fast, Mid and Slow
tissues can be used to achieve user specific decompression profiles.
VR Dive Computer Operations Manual 2009 rev E 28/01/2009